HVACR VIDEOS
HVACR VIDEOS
  • 1 022
  • 53 382 558
THE DINING ROOM AC IS NOT WORKING
HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com
Please consider supporting my channel by
Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos
Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin
By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total purchase (exclusions apply)
Visiting my website and purchasing merch www.hvacrvideos.com
HVAC OVERTIME CHANNEL LINK - ua-cam.com/users/HVACOvertime
Social Media
Facebook HVACR-Videos
Instagram hvacrvideos
For any inquiries please contact me at chris@hvacrvideos.com
Mailing Address
HVACR VIDEOS
12523 LIMONITE AVE.
440 - 184
MIRA LOMA, CA. 91752
Переглядів: 22 377

Відео

THE FREEZER WAS WORKING FINE YESTERDAY
Переглядів 22 тис.21 годину тому
The manager actually told me that he "knocked a bunch of ice off the back of the coil a few days ago" HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUT...
THE WALK IN WONT GET COLD
Переглядів 30 тис.День тому
Be sure to size your solenoid valve's correctly, check out Parker Sporlans Solenoid valve Bulletin 30-10 HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at T...
I LIKE WORKING ON EXHAUST FANS
Переглядів 23 тис.14 днів тому
I like working on exhaust fans HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on your total...
THE FAMILY DINNER HAD TO WAIT
Переглядів 33 тис.21 день тому
The family dinner had to wait... Sometimes when I'm on call my plans get canceled and I gotta fix stuff... HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at...
EXHAUST FAN PROBLEMS
Переглядів 24 тис.21 день тому
This was an interesting one to figure out but when I did it was satisfying. HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the o...
THE BEER WALK IN IS TOO WARM
Переглядів 24 тис.Місяць тому
They got lucky we showed up when we did .... HVACR VIDEOS NEW MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to sav...
THE SMOKE IS ROLLING OUT OF THE HOOD
Переглядів 28 тис.Місяць тому
Lots going on here but I did my best to find the problems. HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICT...
THIS WALK IN COOLER GOT STOPPED BY A BAG
Переглядів 22 тис.Місяць тому
Kinda crazy this thing got stopped by a trash bag on the roof HVACR VIDEOS MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGP...
THE BEER WALK IN COMPRESSOR WONT STOP RUNNING
Переглядів 25 тис.Місяць тому
Trust your gut and dig into stuff HVACR VIDEOS NEW MERCH WEBSITE - www.hvacrvideos.com Please consider supporting my channel by Becoming a Patreon member - Patreon www.patreon.com/Hvacrvideos Becoming a UA-cam channel member ua-cam.com/channels/5Pnrxqqg4BLTsfsUzWw5Pw.htmljoin By purchasing tools via my affiliate links below at TRUTECHTOOLS.COM and use the offer code BIGPICTURE to save 8% on you...
THIS TRANE SPACESHIP JUST STOPPED WORKING
Переглядів 44 тис.Місяць тому
THIS TRANE SPACESHIP JUST STOPPED WORKING
THEY ALL SAID IT WAS THE AC LEAKING WATER
Переглядів 36 тис.Місяць тому
THEY ALL SAID IT WAS THE AC LEAKING WATER
WAS IT REALLY JUST LEFT OFF OR IS THERE MORE TO THE STORY?
Переглядів 33 тис.Місяць тому
WAS IT REALLY JUST LEFT OFF OR IS THERE MORE TO THE STORY?
WHY DOES OUR AC ALWAYS STOP WORKING
Переглядів 30 тис.2 місяці тому
WHY DOES OUR AC ALWAYS STOP WORKING
SOMETIMES WE GET EASY CALLS
Переглядів 21 тис.2 місяці тому
SOMETIMES WE GET EASY CALLS
I DID EVERYTHING I COULD
Переглядів 29 тис.2 місяці тому
I DID EVERYTHING I COULD
OIL OIL ALL OVER THE PLACE
Переглядів 36 тис.2 місяці тому
OIL OIL ALL OVER THE PLACE
THE OFFICE AC IS NOT WORKING
Переглядів 34 тис.2 місяці тому
THE OFFICE AC IS NOT WORKING
MULTIPLE YORK PACKAGE UNIT'S NOT COOLING
Переглядів 38 тис.2 місяці тому
MULTIPLE YORK PACKAGE UNIT'S NOT COOLING
THIS ICE MACHINE WAS INSANE
Переглядів 24 тис.2 місяці тому
THIS ICE MACHINE WAS INSANE
THAT IS AN ODD SOUND FROM THE COMPRESSOR
Переглядів 35 тис.2 місяці тому
THAT IS AN ODD SOUND FROM THE COMPRESSOR
HURRY ALL THE EXHAUST FANS ARE DOWN !
Переглядів 28 тис.2 місяці тому
HURRY ALL THE EXHAUST FANS ARE DOWN !
HURRY THE EXHAUST FAN IS NOT WORKING
Переглядів 29 тис.3 місяці тому
HURRY THE EXHAUST FAN IS NOT WORKING
THEY CALLED ME BACK FOR THIS ICE MACHINE AGAIN
Переглядів 28 тис.3 місяці тому
THEY CALLED ME BACK FOR THIS ICE MACHINE AGAIN
THE KEG COOLER IS TOO WARM
Переглядів 20 тис.3 місяці тому
THE KEG COOLER IS TOO WARM
THE MAIN BREAKER IS TRIPPED AND THE AC IS NOT WORKING
Переглядів 36 тис.3 місяці тому
THE MAIN BREAKER IS TRIPPED AND THE AC IS NOT WORKING
WARM WEATHER IS COMING SUMMER IS UPON US
Переглядів 24 тис.3 місяці тому
WARM WEATHER IS COMING SUMMER IS UPON US
CARRIER EcoBlue PACKAGE UNIT INSTALL
Переглядів 29 тис.3 місяці тому
CARRIER EcoBlue PACKAGE UNIT INSTALL
THEY NEED A NEW WALK IN FREEZER DOOR
Переглядів 25 тис.3 місяці тому
THEY NEED A NEW WALK IN FREEZER DOOR
THE CARRIER PACKAGE UNIT IS NOT COOLING
Переглядів 37 тис.3 місяці тому
THE CARRIER PACKAGE UNIT IS NOT COOLING

КОМЕНТАРІ

  • @MsFireboy2
    @MsFireboy2 3 години тому

    Thanks for posting. Seams like a lot of owners neglect needed maintenance? Also let us talk about the massive Restaurant closures? Your thoughts?

  • @n.gineer8102
    @n.gineer8102 4 години тому

    Under amping can mean it’s not pushing as much air. Was it the original condenser fan motor? And looking clean is deceptive. My personal 3 ton was acting funny and we couldn’t figure out why, so the tech washed it and voila the right pressures; in fact we had slightly overcharged it.

  • @calholli
    @calholli 4 години тому

    I like how it's super dangerous and we don't' want it leaking and filling up the space... So we just vent it into the space. lol. I got a good laugh for that one.

  • @DelticEngine
    @DelticEngine 5 годин тому

    Great video, Chris, packing so much in. I love listening to your thought processes and find them informative and insightful. I have a couple of thoughts: What about using thermal imaging to record temperature rise in the condenser fan motor? It would show a bearing heating up and how hot the motor was getting even if the current draw was within allowed limits. The run capacitor that you replaced could have had intermittent failure. I've known capacitors to partially fail internally and suddenly not perform at all as required, usually due to a voltage surge or spike. When the power is removed from the capacitor 'self-healing' takes place and things appear perfectly normal until the next voltage spike and the cycle repeats. As the capacitor internal condition worsens it takes a smaller an smaller spike or surge to make the problem suddenly appear. Eventually, no more self-healing takes place and the capacitor goes bad for the last time. It's possible a temperature rise may be observed in the capacitor and thermal imaging may help discover this. Otherwise, the only way is to use a dedicated capacitor tester rather than rely on a function built into a multimeter. A proper capacitor tester can reveal far more about a capacitor than a simple measure of capacity. For example, the ESR or Equivalent Series Resistance of a capacitor is a very useful parameter in helping determine the internal health of a capacitor. Any reputable manufacturer will have the full specification of a capacitor available and if they don't I would want to know why and consider using a brand that does.

  • @trcolem
    @trcolem 6 годин тому

    I LOVE EVERYTHING YOU DO FOR US!!! ❤❤❤

  • @sidgysoho1960
    @sidgysoho1960 8 годин тому

    Pace yourself my friend. Like the infrastructure in the U.S. , quite a few pieces of equipment have outlived their useful life and you are the caretaker. But there is just 1 of you ! What the state, nay, the country needs is interested individuals like yourself to get into the trade and help things out ! Used to live in the Detroit MI area and in the 60's there weren't none air conditioning. Until we got a 10.000 BTU sucker for a window, . . ..on 60 amp service. Your skill with the modern machines leaves us mesmerized ! In this VLOG I believe you did the appropriate course of action. Cheers.

  • @josephconway1968
    @josephconway1968 8 годин тому

    Hi Chris. Love your channel. I've been wanting to tell you for a long time now just how much I appreciate how consistent you are with how you do things and how you present information. To me, that is a very valuable quality for a boss, a business owner, a mentor, to have. That is one of the biggest reasons I absolutely love your channel! I know you always say you're not perfect, but your consistency is impeccable!! Thank You for your time.😁😎

  • @navahroneentertainment8126
    @navahroneentertainment8126 8 годин тому

    Can I use r600 in a r290 system?

  • @JamesBarnes-xd9bj
    @JamesBarnes-xd9bj 10 годин тому

    I think I can tell which one is the obvious

  • @JamesBarnes-xd9bj
    @JamesBarnes-xd9bj 12 годин тому

    Don’t look in the attic! Pandoras Box “Polishing a terd” I love it!!!

  • @kamranali1175
    @kamranali1175 12 годин тому

    Hi how are you wake in freezar tamprachar is sloy sloy wat rezan discharge 290 psi and suction 25 psi tamprachar is 0 to -1 time is 30 mint you not mind my inglash is week

  • @hydrogaming1781
    @hydrogaming1781 14 годин тому

    Replace that joint. It is a fire hazard bad 😅😳

  • @thomasdaddy7156
    @thomasdaddy7156 15 годин тому

    Mr show last night I have a question for you in your opinion do you think that the AC units of today are getting way too complicated with all their sensors and crap

  • @uxwbill
    @uxwbill День тому

    Didn't yawn, but I *felt* the tired.

  • @jonathanhughes380
    @jonathanhughes380 День тому

    Thank you for the stream Chris. Hope you are doing well. Have a good night.

  • @vbarbee1
    @vbarbee1 День тому

    2:28 That's great to know. I'm a firefighter and been on AC calls like that. Typically we don't open units unless there is active fire. We're not trained on opening units and not sure what we're doing or what potential problems we can cause doing so. If it's nothing active, we're trained to disconnect power and tell the manager to call their AC repair person. Don't want a business to say we messed up something and try to have the FD pay for a new unit lol. Now we do have a few guys that are electricians and or HVAC ppl.

  • @johnchristou54
    @johnchristou54 День тому

    Ive seen out of spec caps run the fan backwards. Also seeing light through the coil doesnt matter on a micro channel as much as tube and fin. Also good to check the pressure switch itself. I block off coil and watch guages to see if switch cuts out prematurely. Good stuff👍

  • @VooDooV6
    @VooDooV6 День тому

    Came across this same unit today,icing up right after the drier,pulling into a vac...new drier time

  • @justinfidelcastro2861
    @justinfidelcastro2861 День тому

    Love your channel. I like how you put everything in simple terms.

  • @zekenzy6486
    @zekenzy6486 День тому

    Great video. Thank you for sharing

  • @johnthefactfddict3281
    @johnthefactfddict3281 День тому

    I am gonna guess AC is dead because of 1 of three factors 1: some idiot messed with the unit(either during cleaning on the rare customer who does the required maintenance, or just an entitled manager who should not fuck with the thermostat) 2: environmental damage(California is sandy and is like all human lands, full of things disposed of improperly that can ruin motors by jamming them with literal garbage 3: the ducting or some other factor did not match the unit, which has caused it to operate outside of airflow and load conditions(often due to failure to keep air intakes clean, or resize ducts when upgrading unit ratings suprise me HVACR, show me someone who kept their unit in ideal conditions and it is 100% dead to JUST age

  • @mohammedhamideh1002
    @mohammedhamideh1002 День тому

    Could it have been an overamping compressor that could’ve caused the overload ????

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      Good question, I'll discuss this a bit on my next Live Stream this coming Monday

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      I will discuss this on my livestream this evening 7/1/24 @ 5:PM (pacific) on UA-cam come on over and check it out ua-cam.com/users/liver8Zs9swa6cE?si=IXBBHZFjAcTmXHSw

  • @pbehera281
    @pbehera281 День тому

    You guys never do heating related stuff?

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      Yes, but not often because of our warmer climate

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      I will discuss this on my livestream this evening 7/1/24 @ 5:PM (pacific) on UA-cam come on over and check it out ua-cam.com/users/liver8Zs9swa6cE?si=IXBBHZFjAcTmXHSw

  • @davidnull5590
    @davidnull5590 День тому

    Chris, that's a three-phase unit? Are the blower motors three phase? Are the fan motors three phase? Three phase motors DON'T need start capacitors, and three phase motors DON'T need run capacitors. Are the phases correct? Not just running in the correct direction, but are the three phases in the correct sequence? I'm pretty sure you own a special meter for this (remember this is different from motors turning in the correct direction) "The phase sequence of three-phase electricity is the order in which the three phases pass a reference point, usually the red conductor first. The standard phase sequence in most countries is red, yellow, blue (RYB), or 12-4-8, which corresponds to a clockwise rotation:"

    • @WilliamHaggerty
      @WilliamHaggerty День тому

      I would say it is typical for the fans to be single phase, hence the cap.

  • @Critter145
    @Critter145 2 дні тому

    Work at a restaurant. Either the BOH or FOH AC works. Usually never both. It’s hot in Tennessee.

  • @Bubcool210
    @Bubcool210 2 дні тому

    Have always loved your content. Keep it up!

  • @MariosACandRefrigeration
    @MariosACandRefrigeration 2 дні тому

    Manually checking bearings on motor,and using thermal camera on it,could help,hate leaving and getting called back,because it overheated .thanks for the video.

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      Thanks for the tip

    • @MariosACandRefrigeration
      @MariosACandRefrigeration День тому

      @@HVACRVIDEOS if it is a replacement motor,they might have left the drain plug,and it fails when it rains.

  • @matttheaussie2144
    @matttheaussie2144 2 дні тому

    Loving the videos mate, greetings from Melbourne Australia.

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      Thanks for watching from down under

  • @jesse096
    @jesse096 2 дні тому

    I made it about 3 minutes into this video and my sarcasm meter is broken... It really doesn't take much more time to do it right and to clean your mess up... Some peoples kids man, I'm telling you...

  • @ricanderson5717
    @ricanderson5717 2 дні тому

    Yes, you made me yawn, but it's close my bedtime😂

  • @Wethepeople1826
    @Wethepeople1826 2 дні тому

    In the HMI, pressing the top two buttons. If you went into factory settings, temp sensor config, temp sensor 1. Assignment. Preset. Sets the room to 75 degrees factory Would have saved a lot of trouble

  • @dickchez1504
    @dickchez1504 2 дні тому

    I would have done the under load test with that old cap. I think the swap was a good idea and proper fix given info. Meg the motor if you have the means.

  • @karlosflyer
    @karlosflyer 2 дні тому

    Hi Chris!. These intermitent problems are a pain and sometimes the hardests to solve. I'd have changed the fan motor relay as well (cheap). What do you think about measuring condenser motor winding resistance with a megohmeter? Thanks for quality content you share!

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      I will discuss this on my livestream this evening 7/1/24 @ 5:PM (pacific) on UA-cam come on over and check it out ua-cam.com/users/liver8Zs9swa6cE?si=IXBBHZFjAcTmXHSw

  • @catfood9707
    @catfood9707 2 дні тому

    What would you do for a r410 unit that has a low side of 140, a high side of 310 and line temps are almost equal in temps(71 and 76)? I want to learn.

  • @Spencer1609751
    @Spencer1609751 2 дні тому

    Yawning! Stop.

  • @HobbesBaxter
    @HobbesBaxter 2 дні тому

    Yes, you made me yawn! 😂

  • @Michaelgallant171
    @Michaelgallant171 2 дні тому

    Yeah, I’ve found if the caps are going bad the wind can help start the motor and you’ll get intermittent problems, I always make sure when I test the condenser fan motor and suspect a cap the blade is stationary.

  • @ivoryjohnson4662
    @ivoryjohnson4662 2 дні тому

    I am not a HVAC technician but I know how heat can affect electrical components changing the cap was a good call also when you are good you gonna stay busy since you are so tired that means you are good

  • @johnstillman2935
    @johnstillman2935 2 дні тому

    you're exhausted ? you need to think about you and give a little less

  • @ZeroStatic
    @ZeroStatic 2 дні тому

    Chris, try to take care of yourself. You can’t help your customers if you get burnt out. ❤ Sending love from Australia.

  • @helmsajr
    @helmsajr 2 дні тому

    Great job Chris has always.

  • @carloshilarionvazquezaranda
    @carloshilarionvazquezaranda 2 дні тому

    Buenas tardes Chris, como siempre un excelente trabajo y con todo el ánimo de salir adelante ésa actitud que todos deberíamos de tener es admirable en tu persona. Por otro lado si te miras cansado y no me hiciste bostezar Jajaja, Saludos y abrazos a todos ustedes deseando que estén bien y que tú descanses para que recuperes energía. Desde Coacalco Edo de México.

    • @HVACRVIDEOS
      @HVACRVIDEOS 2 дні тому

      Gracias, voy hacer una siesta después de este comentario

  • @fshn76
    @fshn76 2 дні тому

    I feel ya. Been crazy so far this year.

    • @HVACRVIDEOS
      @HVACRVIDEOS 2 дні тому

      This year more so than others

  • @brandoncherry1651
    @brandoncherry1651 2 дні тому

    The tone in this man's voice I feel like he's like a er doctor on cooling heating 💯

    • @TheChipmunk2008
      @TheChipmunk2008 2 дні тому

      you'll be ok we just have to get your head pressure to reduce

    • @HVACRVIDEOS
      @HVACRVIDEOS 2 дні тому

      ​@@TheChipmunk2008lol

  • @sirraident
    @sirraident 2 дні тому

    Quick question, why are we not worried about the suction saturation at 33'f? Sorry for asking because I must have missed something in the explanation.

    • @HVACRVIDEOS
      @HVACRVIDEOS 2 дні тому

      Most of the time we have undersized ductwork causing low airflow but in this case we also had a low load in the building if I remember correctly

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      I will discuss this on my livestream this evening 7/1/24 @ 5:PM (pacific) on UA-cam come on over and check it out ua-cam.com/users/liver8Zs9swa6cE?si=IXBBHZFjAcTmXHSw

    • @sirraident
      @sirraident День тому

      @@HVACRVIDEOS Oh! I didn't realize improper duct size could cause Sat Temp that low unless it was totally blocked. You just reminded me of "ABC" air before charge XD. Thank you! I will totally try to make time for the Q/A!

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 дні тому

    Another great video Chris. Thanks for sharing

  • @dashcamandy2242
    @dashcamandy2242 2 дні тому

    You're right, this summer has been a doozy. Between business increases at Coffee Franchise (and the doubling of staffing levels on every shift but mine because "you never get busy in the afternoons"), car repairs, and crazy weather (thunderstorms, prolonged high temps, insane humidity) I'm already wiped out. I wanted to fix my rear brakes on Friday, but my legs were killing me from Thursday's business, so I had to wait until Saturday. Today, my legs aren't happy with me over yesterday's brake job, and right now walking/standing is excruciating. It's yet another reminder that I'm not as young as I used to be! I'm now telling the twenty-somethings I work with to pick a field they enjoy, work as hard as they can at it, and bank as much money as they can while they're able to, because there's an invisible clock ticking for each of us, and we never know when our bodies are going to tell us it's had enough. But I always add the caveat that "burning the candle at both ends" eventually leads to burn-out, so try to find a healthy work/life balance. Advice I wish I had been given at that age.

  • @TheChipmunk2008
    @TheChipmunk2008 2 дні тому

    Chris if this is at the same place all the time where the 120/208 is consistently low, someone needs to call the power co

    • @TheChipmunk2008
      @TheChipmunk2008 2 дні тому

      the voltage dropping below 200 is unacceptable

    • @TheChipmunk2008
      @TheChipmunk2008 2 дні тому

      they should aim for HIGH end voltages, maybe 215

    • @HVACRVIDEOS
      @HVACRVIDEOS 2 дні тому

      This is a normal thing in the Southern California area, the utility won’t do anything about it

    • @TheChipmunk2008
      @TheChipmunk2008 2 дні тому

      @@HVACRVIDEOS goddamn, that;s not good, undervolting is bad :( ...is it still SCE there?

    • @HVACRVIDEOS
      @HVACRVIDEOS День тому

      I will discuss this on my livestream this evening 7/1/24 @ 5:PM (pacific) on UA-cam come on over and check it out ua-cam.com/users/liver8Zs9swa6cE?si=IXBBHZFjAcTmXHSw

  • @DeclanBirmingham
    @DeclanBirmingham 2 дні тому

    Sweet, another video. Thank you.

  • @NotSexualAtAll
    @NotSexualAtAll 2 дні тому

    4:45 Who did they get to make that app? Why would they put all that goofy slow worthless animation in an app meant for field techs? They must have gone with the cheapest third party possible to make that abomination. Meanwhile, manufacturers, please just put your info on the web where I can search it!!! These apps are terrible!